An RV heater can sometimes be rejetted to burn natural gas, but only if it is a propane-fired combustion appliance designed for a sealed, outside-vented installation and you replace not just the orifice but the gas valve/regulator, burner components, and controls as needed—so in practice the honest answer for most RV furnaces, water heaters, and refrigerators is no, not as a simple “swap the jet” modification. The question also hides a critical ambiguity: “RV heater” can mean a forced-air furnace, a catalytic or radiant space heater, a water heater, or a refrigerator’s cooling unit, and each has a different answer. Below I separate what is physically possible from what is safe, legal, and practical.

First, disentangle “RV heater”

The term covers at least four distinct appliances, and the rejetting question lands differently on each:

Forced-air RV furnaces (Suburban, Atwood/Dometic, Hydro Flame and similar): sealed combustion, a burner inside a heat exchanger, a sail switch, a limit switch, and a control board. These are the appliances most people mean. RV water heaters: often direct-vent or sealed combustion, with a thermocouple or electronic ignition and a gas valve calibrated to propane. RV absorption refrigerators: a small propane flame heats the cooling unit; the “heater” here is a burner tube. Unvented catalytic or radiant space heaters: these burn gas directly into the living space, which changes the safety analysis entirely.

The general principle—gas appliances are matched to a fuel’s heating value, density, and supply pressure—applies to all of them. The practical and legal obstacles differ.

Why propane and natural gas are not interchangeable

Propane (LP) and natural gas differ in ways that make a simple orifice swap insufficient:

Property Propane (LP) Natural gas
Primary constituent C₃H₈ Mostly CH₄
Heating value per volume Roughly 2,500 Btu/ft³ Roughly 1,000 Btu/ft³
Specific gravity vs. air ~1.5 (heavier) ~0.6 (lighter)
Typical appliance supply pressure ~11 in. water column ~7 in. water column (residential)
Air requirement per unit heat Lower Higher

Because natural gas delivers far less heat per cubic foot, a natural-gas orifice must be larger than the propane orifice for the same Btu input—often roughly twice the cross-sectional area, though the exact size depends on the appliance’s rated input and the manifold pressure. That is the “rejetting” part. But the orifice is only one element in a matched system.

What “rejetting” actually involves

A proper fuel conversion is a kit-and-verification job, not a single jet:

1: Orifice change to the manufacturer’s specified natural-gas size for that model and altitude. 2: Gas valve and regulator change or reconfiguration. RV propane appliances use a two-stage regulator at the tank and a valve calibrated for ~11 in. WC. Natural gas at a campsite or home supply point is typically delivered at ~7 in. WC. The appliance’s valve, spring, and regulator must match. 3: Burner and air-shutter adjustment. The primary air opening must be reset for the different stoichiometry; a propane-tuned burner will soot or lift on natural gas. 4: Pilot orifice, thermocouple, and ignition components where applicable; flame-sensing behavior changes with the flame’s shape and position. 5: Manifold pressure verification with a manometer at the appliance, plus a combustion check (flame color, CO in the flue for sealed appliances). 6: Labeling the appliance with the new fuel and input rating.

Manufacturers publish conversion kits for some models—typically for stationary or commercial appliances, and sometimes for RV furnaces intended for long-term park-model or cabin use. Whether a kit exists for your model is the first thing to check, and it is model- and serial-specific. Without a manufacturer’s kit and instructions, you are designing a fuel conversion yourself, which is exactly the situation the standards are written to prevent.

The supply problem: where does natural gas come from?

Even if the appliance could be converted, an RV is mobile. Natural gas is delivered through a utility pipeline at a fixed address, not from a tank you carry. Options people imagine:

Campground pedestal gas: rare; most RV parks supply only electricity, water, and sewer. A few long-term parks or manufactured-home communities have piped gas, usually for park models. Residential quick-disconnect: a homeowner can run a line to an RV pad, but this is a fixed installation with code requirements (sizing, shutoff, regulator, and often a permit). CNG/LNG cylinders: compressed or liquefied natural gas is a vehicle fuel, not a practical appliance supply for a coach, and it requires high-pressure regulation and different safety equipment.

So the realistic use case is a parked RV or park model connected to a permanent gas supply—not a traveling rig. That reframes the project as a fixed-installation conversion, which brings in plumbing and electrical codes as well as the appliance standards.

Codes and standards: the decisive obstacle

In the United States, RV gas appliances are governed by standards such as ANSI/NFPA 1192 (Recreational Vehicles) and NFPA 54/ANSI Z223.1 (National Fuel Gas Code) for the gas piping and appliance connections, with manufacturer instructions (listing) controlling the appliance itself. Key points:

Listed appliances must be installed per their listing. A propane-listed furnace converted to natural gas without the manufacturer’s conversion kit is no longer installed per its listing; an inspector or insurer can treat it as unapproved. Conversions must use listed conversion kits where the manufacturer offers them, and the appliance must be relabeled. Sealed-combustion appliances are especially sensitive: the heat exchanger, burner, and vent are engineered as a unit. A conversion that changes flame characteristics without re-verifying CO levels in the supply air is a carbon-monoxide risk. Local codes and permits apply to any permanent gas line, and some jurisdictions prohibit unlisted conversions outright.

This is why the accurate answer is “possible only within the manufacturer’s conversion path, and otherwise not recommended”—not “yes, buy a jet.”

Safety: why the stakes are high

Carbon monoxide is the central hazard. Propane and natural gas both produce CO when combustion is incomplete, and an improperly jetted burner can produce soot, yellow flame, flame lift, or delayed ignition. In a sealed-combustion RV furnace, a compromised heat exchanger or misadjusted burner can push CO into the living space. Unvented catalytic heaters are worse candidates: they are already marginal for indoor air quality, and converting one changes the catalytic surface’s operating temperature and the appliance’s documented clearance and ventilation requirements. A CO alarm is necessary but not sufficient; it is a backstop, not a design check.

What is realistically answerable for a given rig

Forced-air furnace or water heater with a factory natural-gas conversion kit: possible; follow the kit, verify manifold pressure and combustion, relabel, and have it inspected. Forced-air furnace or water heater without a kit: not recommended; treat as a redesign requiring engineering verification, and expect insurers and inspectors to reject it. Absorption refrigerator burner: conversion kits are uncommon; the cooling unit’s performance depends on precise heat input, so a mismatched burner degrades cooling and safety. Unvented catalytic/radiant heater: strongly discouraged; the appliance’s safety case depends on its rated fuel and ventilation assumptions. Any traveling RV without a fixed gas supply: the conversion has no practical fuel source, so the question is moot.

What is unknown without the specific appliance: the model and serial number, whether a manufacturer’s natural-gas kit exists, the appliance’s rated input and manifold pressure, the altitude of use, and the local code authority. Those are the facts that decide the case, and they cannot be assumed.

Bottom line

Rejetting is the visible tip of a fuel-conversion process that also requires a matched gas valve/regulator, burner adjustment, pressure and combustion verification, relabeling, and code compliance—and a permanent natural-gas supply that most RVs do not have. If a listed conversion kit exists for your exact appliance and you have a fixed gas supply, a qualified gas technician can do it correctly. Otherwise, the safe and code-compliant answer is to keep the appliance on propane or replace it with a natural-gas-listed unit.

This is general educational information, not individual safety, code, or installation advice. Gas appliance conversion involves carbon-monoxide and fire hazards; consult a licensed gas technician and your local code authority, and follow the appliance manufacturer’s instructions for your specific model.