Usually not continuously, and in most RVs not at all without a major upgrade—a quartz heater is a high-wattage resistive load that draws far more power than typical RV solar arrays and battery banks are built to supply for long, and running one from an inverter typically drains a lead-acid or modest lithium bank within an hour or two.
The rest of this answer explains why, in numbers you can check against your own equipment, and where the answer changes.
Why the answer is almost always "no" for a normal RV
A quartz heater—the kind with glowing quartz tubes and a fan, sold as a "quartz infrared" or "radiant" space heater—is a resistance heater. Nearly all of its electricity turns directly into heat, which makes it one of the most power-hungry appliances you can plug into an RV. Common retail units are rated around 1,000 to 1,500 watts, often with two settings (for example, 750 W low and 1,500 W high).
That wattage is the whole story. Solar panels are rated by how much power they can produce in full sun, but a 1,500 W heater running for an hour consumes 1,500 watt-hours (1.5 kWh) of energy. A typical RV solar setup of, say, 400 W of panels produces roughly 1,200–2,000 Wh on a good sunny day in favorable latitudes and seasons—but only while the sun is up, and only if the panels are clean, unshaded, and well-angled. Heat demand peaks at night and in cold, cloudy weather, exactly when solar output is zero or near zero. So even a system that could theoretically "afford" the energy over a full day usually cannot deliver it when the heater is actually needed.
The practical result: a quartz heater is not a realistic continuous load for a typical RV solar system. It is at best a short burst, and even then only with a large inverter and battery bank.
The three bottlenecks, in order
-
The inverter has to be big enough. A 1,500 W heater needs an inverter that can supply at least that much continuous power, plus headroom for startup and for whatever else is running. A 1,500 W resistive load on a 2,000 W continuous inverter is workable; on a 1,000 W inverter it will trip or shut down. Inverter surge ratings are brief and should not be relied on for a heater that runs for minutes or hours.
-
The battery bank has to store enough energy. This is usually the binding constraint. Using the simplified formula:
$$\text{Runtime (hours)} = \frac{\text{usable battery watt-hours}}{\text{heater watts}}$$
A 100 Ah 12 V lithium battery holds about 1,200 Wh nominally; at a safe 80–90% usable depth of discharge, call it roughly 1,000 Wh. That runs a 1,500 W heater for about 40 minutes. A pair of those batteries roughly doubles it to about 80 minutes. A 100 Ah lead-acid battery should only be discharged to about 50%, giving roughly 600 Wh usable—about 24 minutes of 1,500 W heating, and repeated deep draws shorten its life. These are illustrative figures; your usable capacity depends on chemistry, age, temperature, and the inverter's own efficiency loss (typically a few to several percent).
- Solar has to refill what you spent—and it usually can't fast enough. To replace that 1,000 Wh from a 400 W array, you would need several hours of strong sun, and in winter at high latitudes or under cloud, output can be a small fraction of rated power. Cold-weather camping is precisely when panels underperform and when you want the heater most.
A rough sense of scale: to run a 1,500 W heater for eight hours overnight, you would need about 12 kWh of usable storage—on the order of ten 100 Ah 12 V lithium batteries—plus enough solar to recharge them daily, plus a large inverter and heavy wiring. That is a house-scale electrical system, not a typical RV one.
Where the answer changes
The "no" is about typical systems and continuous use. Several situations soften it:
Very small heaters. Some quartz units have a low setting around 400–750 W. A large lithium bank and a 2,000 W inverter can run a 500 W setting for a few hours. It is still an energy-heavy way to heat. Large, purpose-built systems. RVs with 800–1,600 W of solar, 400–800 Ah of lithium, and a 3,000 W inverter can support short heater runs, especially in sunny, mild conditions—but winter boondocking still strains them. Brief use while the sun is high. Running the heater for 20–30 minutes at midday, with surplus solar going straight to the load through the inverter, is far more feasible than overnight use. The energy still comes from the panels in real time. Shore power or a generator. On hookups or with a running generator, the solar system is irrelevant; the heater runs from the external source. Many RVers use a quartz heater this way specifically to avoid burning propane.
What people often confuse
The most common error is treating "the inverter can power it" as "the system can run it." A 2,000 W inverter will happily start a 1,500 W heater for a few minutes—then the batteries sag, the low-voltage cutoff trips, and the heater shuts off. Inverter capacity and energy capacity are different questions.
A second confusion is mixing up watts and watt-hours. "My solar makes 400 watts" does not mean it makes 400 watts all day, and it says nothing about night. Energy storage, not panel wattage, decides whether an overnight heater run is possible.
A third is comparing a quartz heater to a propane furnace or a diesel heater. Those produce heat from fuel, not from the battery, so they use a tiny fraction of the electrical energy. A 12 V fan and controls might draw tens of watts; the heat comes from combustion. That is why RVs are built around propane or diesel heat and why solar-plus-electric heat is such a mismatch.
Finally, note that "quartz heater" is sometimes used loosely. A true quartz radiant heater glows and heats objects and people directly; some ceramic or fan heaters are marketed similarly. The wattage—not the heating element type—determines the electrical demand, so check the label rather than the marketing name.
Practical guidance
If you want to use a quartz heater on solar, treat it as a daytime, short-duration, high-surplus load, size the inverter to at least the heater's wattage with margin, and verify your battery's usable watt-hours against the runtime formula above. For overnight or sustained heat in cold weather, propane, diesel, or a generator is the realistic path; solar is better suited to lights, electronics, fans, and refrigeration. Any specific runtime depends on your battery chemistry, state of charge and temperature, inverter efficiency, solar insolation, and the heater's actual rated draw—all of which you should confirm from your own equipment labels rather than assume.