Yes—a single ceiling or wall fixture can combine an exhaust fan and a light, and many bathroom ventilation products are sold exactly that way, but the combination is a specific product category with its own electrical and installation conditions, not something you should improvise by adding a lamp to an ordinary fan or a fan to an ordinary light.

The question as phrased is genuinely ambiguous, and the ambiguity matters. "Can light exhaust fan fixture" could mean at least four different things: (1) Is there such a thing as a combined exhaust-fan-and-light fixture? (2) Can I put a light bulb or light kit on an existing exhaust fan? (3) Can I add an exhaust fan to an existing light fixture's location or circuit? (4) Can a light fixture and an exhaust fan be controlled together, or share a switch? Each has a different answer, and the evidence supplied speaks to different parts of that picture. This answer addresses all four, while flagging where the question's missing context—product model, jurisdiction, dwelling type, and wiring—determines the result.

What "Combined Fan-Light" Actually Means in the Product Market

Combined fan-light units are a mature, ordinary product category. The supplied product data illustrates two common designs. The Aero Pure AP80-RVL is a recessed ceiling exhaust fan with an integral light: an 80 CFM fan paired with a single PAR30L medium-base lamp (75 W halogen or a 14 W LED equivalent), rated at 1.2 sones, IC-rated for insulation contact, and UL-listed for use in a tub or shower enclosure when GFCI-protected and fitted with the specified lamp. The Aero Pure ABF-L5 is a different configuration entirely: a 110 CFM fan with a dimmable 10 W LED main light and a separate 0.7 W LED nightlight, with the fan, main light, and nightlight capable of being wired separately. These are not the same product with different branding; they differ in lamp type, dimmability, control architecture, and wet-location listing details.

The practical point is that "fan with light" is not a generic capability. It is a product specification. The fixture's listing, its instructions, and its junction-box and lamp ratings define what is permitted. A fixture listed only as an exhaust fan is not thereby listed as a light fixture, and a light fixture is not thereby a fan support.

The Wiring Question: Separate Control vs. Shared Switch

Manufacturers routinely design these units so the fan and light can be operated independently. The Aero Pure AP80-RVL description says the fan and light "can be operated separately or together." The ABF-L5 goes further, with fan, main light, and nightlight "wired separately." The Broan/NuTone installation guide excerpt shows the conventional approach: run 120 V AC house wiring with ground from a power source, through a standard wall switch or an optional double FAN/LIGHT switch, to the junction box in the fan-light housing. In other words, the standard design anticipates either one switch controlling both functions or two switches controlling them separately, depending on how the installer wires the circuit and what the fixture supports.

This is where a lot of confusion arises. "Can they be on the same switch?" and "Can they be on the same circuit?" are different questions. Sharing a circuit is normal; a bathroom fan and light on one 120 V branch circuit is commonplace. Sharing a switch is a design choice, and it has consequences: if the fan and light are on one switch, you cannot run ventilation without lighting the room, and you cannot light the room without running the fan. Many people want the fan on a timer or a separate switch precisely so ventilation can run after the light is off. The fixture's wiring diagram and the switch arrangement determine what is possible; the product listing does not automatically grant separate control.

There is also a control-type distinction worth naming. The AP80-RVL is specified as "Not Dimmable." The ABF-L5 has a dimmable LED main light. If you put a dimmer on a non-dimmable fan-light, you can create flicker, hum, or premature failure, and you may violate the manufacturer's instructions. Dimming a combined unit is not a generic feature; it is a per-product specification that must be checked.

The Installation and Code Side: Boxes, Listings, and Clearances

The retrieved regulatory excerpt is from 24 CFR 3285.702, a federal manufactured-home construction standard, and it addresses ceiling-suspended paddle fans, not exhaust fans. It requires such fans to be connected to a junction box listed and marked for ceiling fan application under NEC Article 314.27(b), installed with blade trailing edges at least 6 feet 4 inches above the finished floor, and wired per the manufacturer's instructions. This is a useful illustration of a general principle—support and box listing follow the load and the product—but it is not a rule about bathroom exhaust fans, and it should not be universalized. A reader who cites it as "the code for exhaust fans" would be misapplying it.

The relevant principles for a combined fan-light are these. First, the fixture must be installed per its listing and instructions; the supplied product data shows IC-rated housings, duct connectors for 4–6 inch ducts, thermal shutoff, and backdraft dampers as typical features, and those are installation requirements, not optional extras. Second, wet-location use is conditional: the AP80-RVL is UL-listed for a tub or shower enclosure only when GFCI-protected and used with a PAR30L bulb; the ABF-L5 is ETL-listed for a tub or shower enclosure when GFCI-protected. A fixture not so listed should not be placed inside a shower or tub zone. Third, the junction box and support must match the fixture's weight and the manufacturer's mounting instructions; a fan-light is heavier and vibrates more than a plain light, and retrofitting one into a box selected for a lightweight luminaire is a common failure point. Fourth, local electrical codes and permit requirements vary by jurisdiction; the supplied sources do not establish a universal rule, and the applicable local code, the product listing, and the installation manual govern.

The Retrofit Question: Adding a Light to an Existing Fan, or a Fan to an Existing Light

This is the part of the query most likely to be literally intended, and it is where the answer must be most careful. Adding a light kit to an existing exhaust fan is sometimes possible—some fans are designed with a light-kit option and a corresponding receptacle, and the Broan/NuTone parts list in the supplied excerpt shows a "LIGHT RECEPTACLE" as a service part, which is consistent with fan models that accept a light. But "sometimes possible" is not "generally permissible." The determining factors are whether the specific fan model is listed for a light kit, whether the kit is the manufacturer's matching kit, whether the housing and wiring support it, and whether the resulting assembly retains its listing. A generic lamp holder screwed into a fan grille is not equivalent, and it can compromise both the fan's listing and the moisture protection.

Going the other direction—putting a fan where a light was—is usually a bigger job than it looks. The existing box may not be rated for fan support, the existing circuit may not be sized or switched appropriately, and the ceiling may not have the clearance or duct path for ventilation. An exhaust fan needs a duct to the exterior, a backdraft damper, and often a roof or wall cap; none of that exists just because a light fixture did. The combined units in the supplied data assume a duct connection and a housing sized for the installation (the AP80-RVL is 8 inches deep; the ABF-L5 is about 10.3 inches deep), which is a real constraint in shallow ceilings.

What the Question Leaves Unknown

Several things the query does not specify would change the answer, and it is worth naming them precisely rather than guessing. The product model matters: whether a given fan accepts a light kit, whether its light is dimmable, what lamp type it takes, and whether it is rated for wet locations are all model-specific. The jurisdiction matters: electrical codes, permit rules, and manufactured-home standards differ, and the supplied 24 CFR excerpt applies to manufactured homes, not to site-built houses generally. The dwelling type matters: a manufactured home, a site-built home, and an apartment with landlord-controlled electrical work have different practical and legal constraints. The circuit and switch arrangement matter: whether there is a spare switched leg, whether the existing box is fan-rated, and whether the fan will be on a timer. And the installation location matters: inside a shower enclosure versus over a dry area changes the GFCI and listing requirements.

What is answerable without those details: combined fan-light fixtures exist and are common; the fan and light can often be controlled separately, but that is a product and wiring specification, not a universal feature; the fixture must be installed per its listing and instructions, with GFCI protection in wet locations and a properly rated junction box and support; and adding a light to a fan or a fan to a light is a product-specific, code-specific, and often permit-specific retrofit that should be checked against the actual model's instructions before purchase or installation. The specific model, jurisdiction, and existing wiring are the missing facts that would let a definitive answer be given.

A Note on Scope

The source category attached to this query—vehicle maintenance and repair parts—does not match the content of the question or the retrieved evidence, which concerns building electrical fixtures. That mismatch is worth flagging because it affects how the answer should be used: the supplied sources are about residential and manufactured-home fan-light fixtures, not about any vehicle system, and no vehicle-specific claim is made here. If the intended question was about a fan or light in a vehicle, the applicable standards and products would be entirely different, and the retrieved evidence would not support an answer.

The general principle that survives across contexts is simple: a combined fixture is a listed assembly, and its permissions come from its listing, its instructions, and the applicable electrical code—not from the fact that a fan and a light can physically coexist in one housing. Where the model, jurisdiction, and wiring are known, the manufacturer's installation instructions and the local electrical authority are the controlling references; where they are not, the honest answer is conditional rather than universal.